AMS DCB-274 manual Pin 7 VIO Reference Input, Input Ports, Standard Mode- Sinking Inputs

Models: DCB-274

1 72
Download 72 pages 34.52 Kb
Page 14
Image 14

ADVANCED MICRO SYSTEMS, INC.

HARDWARE

Pin 7 - VIO Reference Input

This signal defines the input and output voltage range. A “default” voltage of 4.6 volts is derived from the internal +5-volt supply, via a diode. Any external load must be limited to several mA. You may apply an external, higher “VIO” voltage, if appropriate to the application. The input signal thresholds will be approximately ½ of VIO or 2.3 volts. The threshold is the same, independent of PLC or “normal” mode.

Input Ports

All inputs incorporate 10k resistors that may be set as pull-up to the VIO voltage or pull-down to ground as defined by the three-pin “PLC” jumper. When the jumper is in the “PLC” position, (pins 2 and 3 installed) the resistors pull-down and maintain a zero volt level on the inputs. All these inputs will withstand 28 volts DC, even if a lower VIO voltage is used. The possible inputs include; (J1)- ports P1, P2, P3 and P4 (selectable), Jogs (3), Step and Direction and (J4)- Home, Limits (2), Go, and Soft Stop. VIO becomes especially important where outputs drive high voltage devices.

PIN 1

Standard Mode- Sinking Inputs

When the PLC jumper is in the standard mode position (pins 1and 2 installed) the resistors act as pull-up to the VIO supply. Depending on your mode, software commands to invert the signals using the ”l” (lower case L) command may be required for proper operation.

In the “standard” mode, the 10k pull-up resistor will become a pull-down resistor as the input signal exceeds

4.6volts. When the voltage does exceeds 4.6 volts it will cause a pull-down affect because of the internal resistance divider.

Example

When 28 volts is applied to an input, the drive current will be about 0.7 mA per signal. The threshold voltage will increase as each 28-volt signal is applied, approaching 8.5 volts when all are high. The preferred input drive method is open collector (drain) transistor or switch to common (GND).

PLC Mode- Sourcing Inputs

When PLC jumpers (pins 2 and 3) are installed, the pull-up resistors are transformed to pull-down resistors. Activating an input is accomplished by asserting a voltage exceeding ½ VIO on the given input. When these inputs are held low, the logic sense is inverted. For proper operation a mode command must be entered and stored in NV memory. Use the “l” (lower case L) command to configure the inputs. The “l 9” command will invert all of the inputs. The “l 8” command will invert all but the limit switch inputs.

The “l” command defines several configurations. Please refer to the command section for details. These inputs can withstand in excess of 28 volts. The default threshold will remain at 2.3 volts unless an external VIO is supplied.

A higher VIO (i.e., 24 volts from a PLC with 24 volt drivers) would increase the logic threshold to 12 volts, providing better noise immunity.

8

Page 14
Image 14
AMS DCB-274 manual Pin 7 VIO Reference Input, Input Ports, Standard Mode- Sinking Inputs, PLC Mode- Sourcing Inputs