AMS DCB-274 manual Command Format Description, ESC Global Abort, @ Soft Stop

Models: DCB-274

1 72
Download 72 pages 34.52 Kb
Page 39
Image 39

ADVANCED MICRO SYSTEMS, INC.

SMC-27X2 SOFTWARE

Command Format Description

Command

Function

 

Type

 

NV Bytes

 

 

 

 

 

Mnemonic

Data 1

Data 2

Result

 

(Range)

(Range)

 

Where:

Command:

Keystroke

Function:

Functional description of command

Type:

Immediate = Direct execution

 

Program = Executable in stored program

 

Global = All axis present

 

Default = Initial parameter setting

 

Hardware = Auxiliary I/O

NV Bytes:

Storage requirements in program

Mnemonic:

Single character prefix used in multi-axis protocol;

 

(prefixed by axis “name” assignment in party line mode)

Data 1:

Affected parameters

(Range):

Valid numerical range of parameter(s)

Data 2:

Same as Data 1 (as required)

Result:

Information returned as a result of command execution or examination

Note: a comma separates two parameters.

Command

Function

 

Type

NV Bytes

ESC

Terminate Operation

 

Immediate

N/A

 

 

 

 

 

Mnemonic

Data 1

 

Data 2

Result

 

 

 

(Name) Esc Char

None

 

None

Echo #

ESC (Global Abort)

Terminate any active operation and cause the controller to revert to the idle state waiting for a new command. Output drivers or ports are NOT affected. Stepping and position counter update will cease immediately without deceleration. The lack of deceleration can cause mechanical overshoot. The controller will echo a “#” character. This command may not be used within the non-volatile program memory.

Command

Function

 

Type

NV Bytes

@

Soft Stop

 

Immediate, Program

1

 

 

 

 

 

Mnemonic

Data 1

 

Data 2

Result

 

 

 

 

 

 

(Name) @

None

 

None

None

@ (Soft Stop)

If moving, decelerate immediately to a stop using ramp parameters. If running a program, when this command is entered, the program will terminate after deceleration. The soft stop may be embedded in a program without causing termination.

3 3

Page 39
Image 39
AMS DCB-274 manual Command Format Description, ESC Global Abort, @ Soft Stop