ADVANCED MICRO SYSTEMS, INC.

SMC-27X2 SOFTWARE

 

 

 

 

 

 

Command

Function

 

Type

 

NV Bytes

F

Find Home

 

Immediate, Program

3

 

 

 

 

 

Mnemonic

Data 1

Data 2

Result

 

 

(Name) F (n, d)

SPS (40-36,000)

Direction (0,1)

None

F (Find Home)

The special Home algorithm is intended to eliminate mechanical hysteresis typically found in many switches, encoders and is generally present in the form of system mechanical backlash.

The SMC-27X2 microprocessor implements an intelligent homing algorithm whereby home is always approached from the same direction based on the initial logic state of the Home switch and the value (0 or 1) assigned to the “d” direction byte.

Normally Open Home Switch

The Find Home step velocity, using a normally open Home switch (actuation from logic high to low) is programmable over the entire slew velocity available, from 40-36,000 SPS. Once the Home switch is encountered the system inertia typically overshoots the exact switch transition point so that the controller changes the direction signal and shifts the step speed down to the (I) initial parameter velocity. This direction reversal and speed reduction continues until the exact Home switch actuation point is reached and the Homing function is complete.

Normally Closed Home Switch

The Find Home step velocity, using a normally closed Home switch (actuation from logic low to high) will always be the (I) initial velocity parameter setting. Once the Home switch is actuated all motion ceases and the Homing function is complete. The following table illustrates the possible combinations of switch motion:

 

 

 

“d”

 

 

 

 

 

Home Switch

Parameter

Direction of Motion

 

 

 

 

 

 

 

 

 

 

 

 

Normally Open (High to Low)

0

 

Negative

 

 

 

 

Normally Closed (Low to High)

0

 

Positive

 

 

 

 

Normally Open (High to Low)

1

 

Positive

 

 

 

 

Normally Closed (Low to High)

1

 

Negative

 

 

 

 

This command may be implemented within a program. Following, is an example:

 

 

P 0

Enter program mode.

 

 

 

 

 

F 1000 1 Find the home switch in the “1” direction at a step rate of 1000 SPS.

 

 

P

Exit program mode.

 

 

 

 

 

 

 

 

 

 

 

 

Command

Function

 

 

Type

 

 

NV Bytes

G

Execute Program

 

 

Immediate, Program

3

 

 

 

 

 

 

 

Mnemonic

 

Data 1

 

Data 2

Result

 

 

 

 

 

 

(Name) G (a, t)

 

0-192, 256-2048

Trace (0-1)

None

G (Go)

The Go command is used to execute a user programmed sequence starting at location “a.” Most programs will start at “0”, however, you may wish to start at another address. The address MUST begin at a stored instruction address, i.e., “go to” data produces unpredictable results.

3 8