ADVANCED MICRO SYSTEMS, INC.

SMC-27X2 SOFTWARE

Default Table

The following default values are written to NV memory after the ‘Clear’(C 1) command:

Parameter

Value

 

 

Initial Velocity (I)

800 SPS

Slew Velocity (V)

10,000 SPS

Divide Factor (D)

1

Ramp Slope (K)

5

Decay threshold (b)

30

Jog Speeds (B)

90/600

Trip Point (T)

Off

Mode (H)

1/4 micro step

PLC(l)

Off (invert all inputs)

Limit Polarity (l)

Low assert

Auto Position Readout (Z)

Off

Name (after reset)

Unchanged

User Programs (0-191)

Cleared

Turbo Ram

The SMC-27X2 has a small, dedicated memory area called Turbo Ram. There are 64 bytes, which reside between address location 128 and 192. Instructions written here during program mode use “real” internal RAM rather than EEPROM in order to achieve these advantages:

1.Very fast execution. EEPROM access time is 1 Ms. or more per byte.

2.No wear and tear on the EEPROM.

3.The trip service routine executes at address 160.

Macros may be downloaded directly into this area and executed as frequently as desired. Programs in this area are stored in corresponding NV memory and “down -loaded” at power up, making an effective shadow RAM.

Command behavior between address locations128 and 192

Q:List from RAM

P:Program to RAM

S:Copy to EEPROM ]: Write to EEPROM \: Read from EEPROM

C1: Clear EEPROM, reload register

3 2

Page 38
Image 38
AMS DCB-274 manual Default Table, Turbo Ram