Programming

"^" Button Commands (Cont.)

^FON

Set a font to a specific Font ID value for those buttons with a defined address range.

Font ID numbers are generated by the TPDesign4 programmers report. Syntax:

"'^FON-<vt addr range>,<button states range>,<font value>'"

Variable:

variable text address range = 1 - 4000.

button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons 1 = Off state and 2 = On state).

font value = range = 1 - XXX. Refer to the Default Font Styles and ID Numbers section on page 112.

Example:

SEND_COMMAND Panel,"'^FON-500.504&510.515,1&2,4'"

Sets the font size to font ID #4 for the On and Off states of buttons with the variable text range of 500-504 & 510-515.

The Font ID is generated by TPD4 and is located in TPD4 through the Main menu. Panel > Generate Programmer's Report >Text Only Format >Readme.txt.

"^" Button Commands (Cont.)

^GDI

Syntax:

 

 

Change the

"'^GDI-<vt addr range>,<bargraph drag increment>'"

bargraph drag

Variable:

 

 

increment.

 

 

variable text address range = 1 - 4000.

 

 

bargraph drag increment = The default drag increment is 256.

 

Example:

 

 

 

SEND_COMMAND Panel,"'^GDI-7,128'"

 

Sets the bargraph with variable text 7 to a drag increment of 128.

 

 

^GIV

Parameters 1,2, and 3 will cause a bargraph or slider to be inverted regardless of

Invert the joystick

orientation. Their effect will be as described for joysticks.

 

 

 

axis to move the

Syntax:

 

 

origin to another

"'^GIV-<vt addr range>,<joystick axis to invert>'"

corner.

Variable:

 

 

 

 

 

 

variable text address range = 1 - 4000.

 

joystick axis to invert = 0 - 3.

 

 

 

0

1

0 = Normal

 

 

 

1 = Invert horizontal axis

 

2

3

2 = Invert vertical axis

 

3 = Invert both axis locations

For a bargraph 1 = Invert, 0 = Non Invert

Example:

SEND_COMMAND Panel,"'^GIV-500,3'"

Inverts the joystick axis origin to the bottom right corner.