Battery Life and Replacement

Battery Replacement

The touch panel's battery is intended to last the life of the device, but in cases where the battery has reached its effective end of life, it may be replaced with the MVP-BP-52 Battery Pack Kit (FG5966-20). To replace the battery:

1.Shut down the device.

2.Place the device face-down and remove the five screws from the back of the device (FIG. 90).

Two of the screws are at each of the upper corners of the device, underneath screw covers.

Remove the screw covers to access the screws.

Lift up the kickstand to reach the remaining three screws.

IR emitter panel

Upper screw covers

Lower screws

Kickstand

FIG. 90 Screw placement at the back of the MVP-5200i- GW

3.Carefully remove the back of the device, making sure not to dislodge the IR emitter panel.

4.Disconnect and remove the old battery from the female connector (FIG. 91).

5.Connect the new battery, making sure to seat fully the battery’s female connector to the male connector in the device. Use a clean, nonconductive stick or probe to seat the connectors.

6.Install the new battery, making sure that the label faces outward and the battery connector wiring runs to the left (FIG. 91). Make sure that the excess battery wiring fits in the space to the bottom left of the battery.

Excess battery wiring

Battery

Female connector

FIG. 91 Battery installation and connection diagram

7.Reattach the back of the device.

158

MVP-5200i Modero Viewpoint Widescreen Touch Panel

Page 166
Image 166
AMX MVP-5200i manual Battery Replacement, Reattach the back of the device