Protected Setup Pages

G4 Web Control Settings Page

An on-board VNC (Virtual Network Computing) server allows the panel to connect to any remote PC running a VNC client. Once connected, the client can view and control the panel remotely. The options on this page allow you to enable/disable G4 Web Control functionality(FIG. 73).

FIG. 73 G4 Web Control page

Features on this page include:

G4 Web Control Page

Back:

Saves all changes and returns to the previous page.

 

 

Connection Status icon:

The icon in the upper-right corner of each Protected Setup page provides a

 

constant visual indication of current connection status.

 

Note: a Lock appears on the icon if the panel is connected to a secured NetLinx

 

Master.

 

 

G4 Web Control Settings:

Sets the IP communication values for the touch panel:

Enable/Enabled

 

The Enable/Enabled button toggles between the two G4 activation settings:

 

Enable - deactivates G4 Web Control on the panel.

 

Enabled - activates G4 Web Control on the panel.

Network Interface Select

 

Toggles between the two network interface options:

 

Wireless - the panel is communicating via a Wireless Access Point (WAP).

 

• Wired - the panel is communicating via its mini-USB port.

Web Control Name

 

Use this field to enter a unique alpha-numeric string to be used as the panel’s

 

display name within the Manage WebControl Connections window of the

 

NetLinx Security browser window.

Web Control Password

 

Use this field to enter the G4 Authentication session password required for

 

VNC access to the panel.

Web Control Port

 

Use this field to enter the number of the port used by the VNC Web Server.

 

Default = 5900.

 

 

Maximum Number of

Displays the maximum number of users that can be simultaneously connected

Connections

to this panel via VNC. Default = 1.

Current Connection Count

 

Displays the number of users currently connected to this panel via VNC.

 

 

G4 Web Control Timeout:

Sets the length of time (in minutes) that the panel can remain idle, detecting no

 

cursor movements, before the G4 Web Control session is terminated.

 

• Minimum value = 0 minutes (panel never times out)

 

• Maximum value = 240 minutes (panel times out after 240 minutes)

 

 

MVP-5200i Modero Viewpoint Widescreen Touch Panel

87

 

 

Page 95
Image 95
AMX MVP-5200i manual G4 Web Control Settings, G4 Web Control Timeout