Upgrading Firmware

7.Select Tools > Firmware Transfers > Send to NetLinx Device from the main menu to open the Send to NetLinx Device dialog (FIG. 84). Verify that the panel’s System and Device number values match those values listed within the System folder in the OnLine Tree tab of the Workspace window.

FIG. 84 Send to NetLinx Device dialog window

8.Select the appropriate Kit file from within the Browse for Folder window (FIG. 85).

FIG. 85 Browse for Folder window

9.Select the panel’s Kit file from the Files section.

10.Enter the Device value associated with the panel and the System number associated with the Master (listed in the OnLine Tree tab of the Workspace window). The Port field is greyed-out.

11.Click the Reboot Device checkbox if it is not already checked. This causes the touch panel to reboot after the firmware update process is complete.

12.Click Send to begin the transfer. The file transfer progress is indicated on the bottom-right of the dialog.

13.After the file transfer is complete, the panel will automatically reboot. As the panel is rebooting, temporarily unplug the USB connector on the panel until the panel has completely restarted.

14.Once the first panel page has been displayed, reconnect the USB connector to the panel.

15.Right-click the associated System number and select Refresh System. This causes a refresh of all project systems, establishes a new connection to the Master, and populates the System list with devices on your particular system.

MVP-5200i Modero Viewpoint Widescreen Touch Panel

99

 

 

Page 107
Image 107
AMX MVP-5200i manual Send to NetLinx Device dialog window