Configuring Communication

Ethernet

1.When using Wireless Ethernet, press the listed Mode to toggle through the available connection modes:

Connection Modes

Mode

Description

Procedures

 

 

 

None

No connection

None

 

 

 

Auto

The device connects to the first master that

Setting the System Number:

 

responds. This setting requires setting the

1.

Select the System Number to open the keypad.

 

System Number.

 

2.

Set your System Number and select Done.

 

 

 

 

 

URL

The device connects to the specific IP of a

Setting the Master IP:

 

Master via a TCP connection. This setting

1.

Select the Master IP number to the keyboard.

 

requires setting the Master’s IP.

 

2.

Set the Master IP and select Done.

 

 

 

 

 

Listen

The device "listens" for the Master to initiate

Confirm that the device IP is on the Master URL

 

contact. This setting requires providing the

list. Set the Host Name on the device and use it to

 

Master with the device’s IP.

locate the device on the Master. Host Name is

 

 

particularly useful in the DHCP scenario, where

 

 

the IP address can change.

 

 

 

 

2.Select the Master Port Number to open the keypad and change this value. The default setting for the port is 1319.

3.Set the Master Port and select Done.

4.If you enabled password security on your Master, set the username and password within the device.

5.Select the blank field Username to open the keyboard.

6.Set the Username and select Done.

7.Select the blank field Password to open the keyboard.

8.Set the Password and select Done.

9.Press the Back button to return to the Protected Setup page.

10.Press the Reboot button to reboot the device and confirm changes.