2.1.2 Recommended Installation Tools
You will need the following tools and equipment (not included) to install the switch into an equipment rack:
• Flat head screwdriver
• Phillips head screwdriver
• Antistatic mat or foam
2.1.3 Power Requirements
The electrical outlet should be located near the switch and be easily accessible. It must also be properly grounded.
Make sure the power source adheres to the following guidelines:
•Power: Auto Switching 110/240 VAC
•Frequency range: 50/60 Hz
•Maximum Input AC Current: 1.0A at 115 VAC full load
2.1.4 Environmental Requirements
The switch must be installed in a clean, dry,
•Operating Temperature: 0° to 40° C (32° to 104° F)
•Storage Temperature:
•Relative Humidity: 10% to 90%
•Storage Relative Humidity: 10% to 95%
Avoid direct sunlight, heat sources, or areas with high levels of electromagnetic interference.
2.1.5 Cooling and Airflow
The IntraCore 3500 series switches use internal fans for
2.2 Installation into an Equipment Rack
To install the unit in an equipment rack, use the following procedure:
Important! Before continuing, disconnect all cables from the unit.
1.Place the switch on a flat, stable surface.
2.Locate a
3.Use the screws (supplied) to secure the bracket (with a Phillips screwdriver).
4.Repeat the two previous steps on the other side of the unit.
5.Place the switch in the equipment rack.
6.Secure the switch by securing its mounting brackets onto the equipment rack with the appropriate screws (supplied).
Important! Make sure the unit is supported until all the mounting screws for each bracket are secured to the equipment rack. Failure to do so could cause the unit to fall, which may result in personal injury or damage to the unit.
13