Installing Second Power Supply

Installing GBIC Interfaces

If you have installed modules for GBIC interfaces, install each interface itself by sliding it into the port, until the locking tabs on either side of the GBIC interface unit click into the locked position. You can then connect the SC-type fiber media.

To remove a GBIC interface, squeeze the locking tabs against the sides of the unit until they release it, then slide the interface out of the port.

Installing Second Power Supply

To install a power supply module in your IntraChassis 9000, first loosen and undo the thumbscrew holding the cover plate, then remove the plate and slide the second power supply into the chassis from the front, as shown in Figure 2-2. Tighten the thumbscrew to hold the power supply firmly in place.

Connecting Power

To connect power to the IntraChassis 9000, use the following procedure.

Important: Carefully review the power requirements on page 2-4 before connecting power to the IntraChassis 9000.

1 If you have purchased a second power supply, insert it in the bay provided at the bottom of the IntraChassis 9000 chas- sis, as shown in Figure 2-2.

2 Plug one end of the supplied power cord into the power connector on the back of the unit.

3 Plug the other end into a grounded AC outlet.

Important: If the power does not come on, refer to Appendix A, “Troubleshooting.”

The IntraChassis 9000 is ready for connection to the network.