After creating RAID groups

1If you are not already in the ExpressNAV Storage Manager, type the IP address of your appliance in a standard browser. On the splash screen, click Enter Here. In the box provided, type in your user name and password, and click OK.

2Click on the Diagnostics button on the left hand side of the ExpressNAV Storage Manager.

3Choose either Initialize and Verify Drives or Read-Only Drive Test from the Select User Process menu.

4Click Next.

5If no drives appear in the information box, click on the System Scan button.

If drives are available, click on the drives you wish to verify, initialize or test; the drives are highlighted.

6 Click Commit.

CAUTION

Do not restart the FastStream or disconnect or power cycle drives during Drive Initialization and Verification or you must start the verification process from the beginning.

7A warning box appears. In the warning box, verify that you want to complete the configuration by clicking on Yes. Clicking on No ends the procedure without making a change.

8If you chose to initialize and verify drives, the Health and Status Monitor page appears and all data on the previously-highlighted drives has been erased.

If you chose to do a read-only test, the Drive Performance and Health page appears showing what tests are running and their results. You may select other tests to run or continue on to other tasks.

12

Page 17
Image 17
ATTO Technology SC 5700 operation manual After creating RAID groups