PassThroughRediscover
SC 5500, 5700
Makes any
PassThroughRediscover
Password
Specifies the password used for all sessions. Password is case sensitive, 0 to 32 characters, and cannot contain spaces. An empty password can be configured by pressing the enter key when prompted for the new password and new password confirmation.
Default: Password set Password
Performance
Lists the performance data for the
get Performance <fp>
Ping
Sends an ICMP echo request to the specified host.
ping [mp1] [xxx.xxx.xxx.xxx] <count <size>>
RAIDRebuildPriority
Regulates or displays the RAID rebuild priority. A RAID rebuild priority set to high gives higher priority to RAID rebuilds and lower priority to the processing of simultaneous I/O transactions. A RAID rebuild priority set to low gives lower priority to the rebuild and a higher priority to I/O transactions. Set same, the RAID rebuild and processing of I/O transactions is the same.
Default: same
set RAIDRebuildPriority <GroupName all> [high low same]
SaveConfiguration command required
get RAIDRebuildPriority <GroupName all>
RAIDSpeedWriteLimit
Regulates the limit on the coalescing factor. A very low limit is recommended for multiple initiators; a high limit is recommended for multiple streams of sequential write I/O.
Default: 8
set RAIDSpeedWriteLimit
ReadOnlyPassword
Specifies a password which allows only read and no writes. It is case sensitive, 0 to 32 characters, and cannot contain spaces. An empty password can be configured by not specifying one.
Default: Password
set ReadOnlyPassword
ReadOnlyUsername
Specifies the user name which allows only read and no writes. It is case insensitive, 1 to 32 characters, and cannot contain spaces.
Default: user
set ReadOnlyUsername [username] get ReadOnlyUsername
Reserve
Reports the state of CLI reservation for the current CLI session. If the command reports that Reservations are enabled, then another CLI session has control of parameter modification on the unit.
Reserve
ResetFCPortErrors
Changes all Fibre Channel error counts for the specified port to zero. Refer to FCPortErrors.
ResetFCPortErrors [fp all]
RestoreConfiguration
Issued with the default option, forces the unit NVRAM settings to their original defaults. The factory option forces the NVRAM setting ot its original defaults and the unit’s original World Wide Name. The saved option undoes any changes made to this session since the last save.
RestoreConfiguration [Default Factory Saved]
RGAddStorage
Adds additional storage to an existing RAID group. MIRROR STRIPE SPAN specifies the method used to expand the storage. If the BlockDevID is omitted, the CLI command RGMemberAdd must be used. Optional parameter commit specifies that the RGCommit command is run automatically and all user data is erased from each new member drive. If the parameter is omitted, the CLI command RGCommit must be entered. You may enter several BlockDevIDs before the commit parameter. Any time before RGCommit is entered, the command RGCancelAddStorage can to used to end the process.
Note
MIRRORs can not be added to a RAID 4, 5 or DVRAID group.
RGAddStorage [GroupName] [MIRROR STRIPE SPAN] <BlockDevID>... <commit>>
xii