ATTO Technology SC 5700 IPSubnetMask, IsReserved, MaxOpTemp, Metrics, MinOpTemp, OpTempWarn

Models: SC 5700

1 73
Download 73 pages 30.77 Kb
Page 58
Image 58

IPSubnetMask

Controls the current subnet masks used by any Ethernet port(s) on the unit. If IPDHCP is enabled, the get command reports the current IP subnet mask assigned by the network DHCP server.

Default: 255.255.0.0

set IPSubnetMask [mp1] [xxx.xxx.xxx.xxx] SaveConfiguration Restart command required get IPSubnetMask [mp1]

IsReserved

Displays the reservation status of the current unit.

IsReserved

MaxOpTemp

Regulates the maximum operating temperature of this unit in degrees Celsius. Valid entries are between 55 and 70 degrees.

Default: 70

set MaxOpTemp [55 – 70] SaveConfiguration Restart command required get MaxOpTemp

Metrics

Controls the collection of standard data metrics within a product.

Metrics [Start Stop Display Clear] [[drive [BlockDevID] all running]

MinOpTemp

Regulates the minimum operating temperature of this unit in degrees Celsius. Valid entries are between 0 and 15 degrees.

Default: 0

set MinOpTemp [0 – 15]

SaveConfiguration Restart command required get MinOpTemp

OpTempWarn

Regulates the number of degrees Celsius before a thermal control event precipitates a warning to the user. Valid entries are between 0 and 15 degrees.

Default: 5

set OpTempWarn [0 – 15]

SaveConfiguration Restart command required get OpTempWarn

Partition

Sets the specified partition to the specified capacity in gigabytes (GB), megabytes (MB), or blocks. The specified capacity must be smaller than the specified partition’s current capacity. A new partition is created to acquire the remainder of the original partition’s space. VirtualDriveInfo displays characteristics and statistics for all the available virtual drives or any available virtual drive identified by its virtual drive ID.

Partition [GroupName] [partition index] [capacity] [GB MB blocks]

xi

PartitionDisplay

Lists all the partitions available in the specified RAID group. The partitions are listed in order of contiguousness (as opposed to index order).

PartitionDisplay [GroupName]

PartitionMerge

Combines the specified contiguous partitions into one partition. Partition index is the index of a partition to merge, along with a number of contiguous partitions to merge to that index. All indicates that all partitions in the RAID group are merged into a single Virtual Disk. The RAID group must not be in a NEW state. None of the partitions to merge may be mapped.

PartitionMerge [GroupName] [[[partition index] [2-128]] all]

PartitionSplit

Divides the specified partition into one or more partitions whose capacities are evenly distributed among the capacity of the original partition. The partition to split cannot be mapped. The RAID group must not be in a NEW state.

PartitionSplit [GroupName] [partition index] [2-128]

PartitionWriteCache

If enabled, allows higher write performance with a small risk of data loss after a system failure. If disabled, provides a higher level of data integrity with lower write performance.

set PartitionWriteCache [GroupName] {PartIndex] [enabled disabled]

get PartitionWriteCache [GroupName] {PartIndex]

PassThroughMode

SC 5500, 5700

Specifies the non-disk device types which are automatically mapped at boot time. The all option allows all non-disk devices to be mapped. The SES option allows dedicated SES processor LUNs to be mapped. The non-SES option allows all non-SES devices to be mapped. The disabled option disables the pass- through mode.

Default: disabled

set PassThroughMode [all SES non-SES disabled] get PassThroughMode

PassThroughPersistent

SC 5500, 5700

Stores maps for currently-attached passthrough devices to persistent memory,

PassThroughPersistent

ATTO Technology Inc. FastStream SC Installation and Operation Manual

Page 58
Image 58
ATTO Technology SC 5700 IPSubnetMask, IsReserved, MaxOpTemp, Metrics, MinOpTemp, OpTempWarn, PartitionDisplay