SCSIPortList

SC 5300

Lists the status of all available SCSI ports.

SCSIPortList

SCSIPortReset

SC 5300

Resets the specified SCSI bus.

SCSIPortReset [sb]

SCSIPortResetOnStartup

SC 5300

Controls whether the specified SCSI bus is reset each time the unit is powered up.

Default: enabled

set SCSIPortResetOnStartup [sb] [enabled disabled] get SCSIPortResetOnStartup [sb]

SCSIPortSyncTransfer

SC 5300

Controls the unit’s attempts to negotiate synchronous SCSI transfers with devices on the specified bus.

Default: enabled

set SCSIPortSyncTransfer [sb] [enabled disabled] get SCSIPortSyncTransfer [sb]

SCSIPortTermination

SC 5300

Configures the SCSI internal termination of the specified SCSI port. Enabling termination allows the unit to act as a terminator at the end of a SCSI chain.

Default: enabled

set SCSIPortTermination [sb] [enabled disabled] get SCSIPortTermination [sb]

SCSIPortWideTransfer

SC 5300

Controls the unit’s attempts to negotiate wide SCSI transfers with devices on the specified bus.

Default: enabled

set SCSIPortWideTransfer [sb] [enabled disabled] get SCSIPortWideTransfer [sb]

SCSITargetLUNs

SC 5300

Controls the maximum number of SCSI LUNs per target the unit queries during a SCSI bus scan.

Default: 8

set SCSITargetLUNs [sb] [8 64] get SCSITargetLUNs [sb]

SCSITargets

SC 5300

Lists the physical devices that are connected and running on the specified SCSI port.

SCSITargets [sb]

SerialNumber

Displays the serial number of the unit. The serial number is a 13 character field. The first seven alphanumeric characters are an abbreviation representing the product name. The remaining six digits are the individual unit’s number.

get SerialNumber

SerialPortBaudRate

Configures the baud rate for the unit’s RS-232 serial port. The number of data bits per character is fixed at 8 with no parity.

Default: 115200

set SerialPortBaudRate [9600 19200 38400 57600 115200]

SaveConfiguration Restart command required get SerialPortBaudRate

SerialPortEcho

Controls if the unit echoes characters on its RS-232 port. When enabled, all non-control character keyboard input is output to the display.

Default: enabled

set SerialPortEcho [enabled disabled] get SerialPortEcho

SES

SC 5500, SC 5700

Enables support for SES enclosures that have been discovered by the appliance.

Default: enabled

set SES [enabled disabled] get SES

SESAlarmTest

SC 5500, SC 5700

Turns on the specified enclosure's audible alarm at the specified warning level. Reset turns off the alarm.

Note

The SESEnclosures command must be executed before executing

SESAlarmTest [EnclosureIndex] [SET RESET] [INFO

NON-CRIT CRIT UNRECOV]