ATTO Technology SC 5700 operation manual CLI command explanations, AutoMap, AutoResume

Models: SC 5700

1 73
Download 73 pages 30.77 Kb
Page 53
Image 53

Command

Default

Example

 

 

 

SESDiskFailureAlarm (SC 5500, 5700)

disabled

set sesdiskfailurealarm enabled

 

 

 

SESEnclosures (SC 5500, 5700)

 

sesenclosures

 

 

 

SESIdentify (SC 5500, 5700)

 

set sesidentify RAID g1

 

 

 

SESIdentifyStop (SC 5500, 5700)

 

sesidentifystop all

 

 

 

SESMute (SC 5500, 5700)

mute

sesmute remind

 

 

 

SESPoll (SC 5500, 5700)

60

set sespoll 20

 

 

 

SESStartingSlot (SC 5500, 5700)

1

set sesstartingslot 2

 

 

 

SESStatus (SC 5500, 5700)

 

sesstatus

 

 

 

SNTP

enabled

get sntp

 

 

 

SNTPServer

192.43.244.18

set sntpserver 129.6.15.28

 

 

 

TailEventLog

 

taileventlog

 

 

 

Temperature

 

get temperature

 

 

 

Time

 

set time 03:32:30

 

 

 

TimeZone

EST

set timezone pst

 

 

 

Username

root

set username Barbara

 

 

 

VerboseMode

enabled

set verbosemode disabled

 

 

 

VirtualDriveInfo

 

virtualdriveinfo

 

 

 

Voltage (SC 5300, 5700)

 

get voltage

 

 

 

WrapEventLog

enabled

set wrapeventlog disabled

 

 

 

zModem

 

zmodem receive

 

 

 

CLI command explanations

Command Line Interface commands are listed alphabetically with explanations of what they are used for, their defaults and syntax.

CAUTION

Using CLI without contacting an ATTO technician is not recommended because changing parameters may cause loss of data and/or disruption to performance and reliability of the FastStream.

The ExpressNAV Storage Manager is the preferred method to manage the FastStream. Refer to Interface Options on page 39 for details.

AutoMap

Automatically assigns a subset of source protocol LUNs to a subset of target destination devices visible to the unit. The unit reports a five-second delay while it scans for devices. All previous maps are deleted.

If FCMultiNode is enabled (multiple node): AutoMap <fp>

SaveConfiguration command required

If FCMultiNode is disabled (single node): AutoMap SaveConfiguration command required

AutoResume

Regulates the AutoResume features for interrupted initialization, rebuild and erase operations at startup. If no GroupName is specified, all existing RAID groups are affected.

Default: enabled for AutoResume Initialize, Rebuild disabled for AutoResumeErase

set AutoResume [Initialize Rebuild Erase All ] [enabled disabled] <GroupName>