ATTO Technology SC 5700 operation manual Disk Stripe Data

Models: SC 5700

1 73
Download 73 pages 30.77 Kb
Page 69
Image 69

RAID Level 6: striping, two parity blocks distributed among drives

RAID Level 6 increases reliability for mission critical applications by striping both data and dual parity across multiple drives, writing data and parity blocks across all the drives in a RAID group. RAID 6 provides

can tolerate failure of two drives and provides redundancy during rebuilds.

The ATTO FastStream requires at least four drives to build a RAID 6 group. Two drives per RAID group are used for parity protection and are unavailable for data.

 

Disk 1

Disk 2

Disk 3

Disk 4

Disk 5

Stripe 1

Data 1

Data 2

Data 3

Parity 1-3

Parity 1-3

Stripe 2

Data 5

Data 6

Parity 4-6

Parity 4-6

Data 4

Stripe 3

Data 9

Parity 7-9

Parity 7-9

Data 7

Data 8

Stripe 4

Parity 10-12

Parity 10-12

Data 10

Data 11

Data 12

 

xxii