Chapter 2: SNMP configuration

9.Use the command set spantree version rapid-spanning-tree to set the spanning tree version to rapid-spanning-tree. Do not use the default.

Note:

This command is available on Avaya Ethernet switches with firmware version 4.0 or later. To use this command, you must update the firmware to this version, if necessary.

For more information on the spanning tree CLI commands, see Installation and Configuration Guide, Avaya C360 and Reference Guide, Avaya C360. These documents are available at the Avaya Support Web site http://www.avaya tha.com/support.

10.If the port networks are IP-PNC, ensure that all appropriate ports on the Ethernet switch are locked to 100 speed and full duplex.

11.When you finish, disconnect your computer from the Ethernet switch.

12.If two Ethernet switches are present for CNA, repeat Steps 1 through 10 for the second switch.

13.If the control network is duplicated, repeat Steps 1 through 11 for each Ethernet switch that remains.

30 Installing and Configuring the Avaya S8700-Series Server

January 2008

Page 30
Image 30
Avaya S8700 manual Snmp configuration