Chapter 3: Communication Manager installation
Applying power to the server
Note:
In this procedure, the software
1.Connect the AC power cord to server 1 and to UPS 1.
2.Press the Power button on the front of the server. Immediately place the Avaya Communication Manager
Accessing the server
1.Use a
2.Wait at least 3 minutes after you turn on the server before you start a Telnet session to access the information on the
Configuring Telnet for Windows 2000 and Windows XP
The Microsoft Telnet application might be set to send a carriage return (CR) and a line feed (LF) whenever you press Enter. The Communication Manager installation program sees this as two separate key presses. If you are running Windows 2000 or Windows XP, you must correct this setting before you copy the Remaster Program to the hard disk drive.
1.Click Start > Run to open the Run dialog box.
2.Type telnet and press Enter to open a Microsoft Telnet session.
3.Type unset crlf and press Enter.
4.Type display and press Enter to verify that you see the message Line feed mode - Causes return key to send CR.
5.Type q and press Enter to exit the telnet session.
32 Installing and Configuring the Avaya | January 2008 |