Chapter 2: SNMP configuration

Table 5: Default values for a dedicated control network shows the default values for Ethernet switch 1 and Ethernet switch 2 for a dedicated control network.

For non-dedicated control networks, the customer will provide IP addresses

! Important:

Do not use the IP address of the active server.

Table 5: Default values for a dedicated control network

Parameter

Ethernet

Single control

Duplicated control

 

switch

network (CNA)

network (CNB)

 

 

 

 

IP address

1

198.152.254.240

198.152.255.240

Subnet mask

 

255.255.255.0

255.255.255.0

 

 

 

 

IP address for the

1

198.152.254.201

198.152.255.201

trap receiver (server 1)

 

 

 

IP address

2

198.152.254.241

198.152.255.241

Subnet mask

 

255.255.255.0

255.255.255.0

 

 

 

 

IP address for the

2

198.152.254.202

198.152.255.202

trap receiver (server 2)

 

 

 

 

 

 

 

Preparing to configure the Ethernet switch

Before you configure the Ethernet switch, you must complete the following prerequisites:

The Ethernet switch power cord is connected to the back of the switch and to the back of a UPS.

-For a single control network, connect the Ethernet switch 1 for Control Network A (CNA) into UPS 1.

-For a duplicated control network, connect the Ethernet switch 1 for CNA into UPS 1 and connect the Ethernet switch 2 for Control Network B (CNB) into UPS 2.

The communication protocol on your computer has the following port settings so that you can use your terminal emulation program:

-9600 baud

-No parity

-8 data bits

-1 stop bit

-No flow control