Chapter 8: Installation verification

This chapter provides the following information about how to verify the server installation and configuration:

Testing the IPSI circuit packs

Testing the license file

Checking LED status indicators

-Servers

-Avaya Ethernet switches

-Uninterruptible power supplies (UPSs)

-Circuit packs

Testing the IPSI circuit pack

The following steps test the clock and packet interface components within the TN2312BP IPSI circuit pack.

Note:

With duplicated servers, use the active server.

1.In a SAT command line, type test ipserver-interfaceUUC and press Enter, where UUC is the cabinet and the carrier in which the circuit pack is located.

2.Verify that the Test Results screen shows PASS in the Results column.

Testing the license file

! Important:

Wait at least 30 minutes after you install the Communication Manager license before you run this test.

Note:

With duplicated servers, use the active server.

1.On a SAT command line, type test license and press Enter.

2.Verify that the Test Results screen shows PASS in the Results column.

Installing and Configuring the Avaya S8700-Series Server

January 2008 75

Page 75