flash

Press any A-16R button to acknowledge the transfer status message and return the A-16R to normal operation.

Loading an All Preset File via MIDI

As when loading a single Preset via SysEx, to load an All Preset data file the A-16R must first be placed into MIDI Recall Mode.

The A-16R will remain in MIDI Recall until a valid A-16R MIDI message is received, or until another front panel button is pressed to exit MIDI mode. MIDI SysEx information for other manufacturer’s devices will pass through the A-16R and be ignored.

To load an All Preset data file via SysEx:

1.Set the A-16R front panel REMOTE/LOCAL switch to the LOCAL position.

2.Press the RECALL button. The RECALL button LED flashes.

3.Press the SOLO button to arm the A-16R for MIDI reception. The LED in the SOLO button will blink.

4.Send the All Preset SysEx data file from your MIDI storage device.

5.The sixteen Presets are loaded into the A-16R internal memory sequentially.

6.The Mute LEDs will serve as a progress bar. The LEDs will light in order from 1 to 16 as each Preset is received successfully.

When the All Preset SysEx file transfer is complete, the system will display a status message to confirm that the data was received properly. Two messages are possible:

Valid Data Received - all yellow Mute LEDs will flash

Invalid Data or MIDI Error - all red Channel LEDs will flash

Press any A-16R button to acknowledge the transfer status message and return the A-16R to normal operation.

Exit MIDI Mode

You can exit an All Preset SysEx load operation by pressing any A-16R front panel button, or by changing the position of the Remote/Local switch. Presets that have been successfully received prior to exiting the SysEx recall mode will be preserved in the internal memory of