LIGHT GAUGING

LABEL&

 

ULTRASONIC

 

SLOT

 

LIGHT

 

lUMINESCENCE

MEASURING

 

 

SCREENS

&

 

COLOR

 

TEMPERATURE

 

LIGHT-TO-

 

PICK

 

RADAR

 

MEASUREMENT & INSPECTION

U-GAGE

T30U, 15-24V dc

 

 

 

 

PDF

®

 

 

 

 

 

 

 

Download

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Discrete

Analog

Response

Data

Models*

 

Range

Frequency

Cable**

Output(s)

Output

Time

Sheet

T30UUNA

 

 

 

2 m

NPN

 

 

 

 

 

 

 

 

 

 

 

T30UUNAQ

 

150 mm - 1 m

228 kHz

5-pin Euro QD

0 to 10V dc

48 ms

 

 

 

 

 

 

 

 

 

T30UUPA

 

2 m

PNP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T30UUPAQ

 

 

 

5-pin Euro QD

 

 

57438

 

 

 

 

 

 

T30UUNB

 

 

 

2 m

NPN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T30UUNBQ

 

300 mm - 2 m

128 kHz

5-pin Euro QD

0 to 10V dc

96 ms

 

 

 

 

T30UUPB

 

2 m

PNP

 

 

 

 

 

 

 

 

T30UUPBQ

 

 

 

5-pin Euro QD

 

 

 

 

 

 

 

 

 

 

*For sensors with Teflon®-protected face and transducer (long-range models only), add suffix -CRFVto the model number (example, T30UUNB-CRFV). ** For 9 m cable, add suffix W/30 to the 2 m model number (example, T30UUNA W/30). A model with a QD requires a mating cable (see page 415).

Teflon®-encapsulated models have a range of 300 - 1.5 m.

 

U-GAGE®T30U Specifications

 

Sensing Range

“A” suffix models: 150 mm min. near limit; 1 m max. far limit

 

 

B” suffix models: 300 mm min. near limit; 2 m max. far limit

 

 

“-CRFV” models: 300 mm min. near limit; 1.5 m max. far limit

 

Effective Beam

See charts EBPC-8,EBPC-9,EBPC-10,EBPC-11 and EBPC-12 on page 514.

 

 

 

 

 

Supply Voltage

Current sourcing analog output models: 12 to 24V dc (10% max. ripple); 90 mA (exclusive of load)

 

Voltage sourcing analog output models: 15 to 24V dc (10% max. ripple); 90 mA (exclusive of load)

 

Dual-discrete output models: 12 to 24V dc (10% max. ripple); 90 mA (exclusive of load)

 

Ultrasonic Frequency

Short Range: 228 kHz

 

 

Long Range: 128 kHz

 

Supply Protection Circuitry

Protected against reverse polarity and transient voltages.

 

 

 

 

 

Output Protection

Protected against continuous overload and short-circuit; transient over-voltage; no false pulse on power-up.

 

 

 

 

Output Configuration

Discrete (switched) output: Solid-state switch conducts when target is sensed within sensing window;

 

choose NPN (current sinking) or PNP (current sourcing) models.

 

 

Analog output: Choose 0 to 10V dc sourcing or 4 to 20 mA sourcing output models;

 

 

output slope may be selected using TEACH sequence.

 

 

 

 

 

 

Output Ratings

Discrete (switched) output: 100 mA max., total–both outputs

 

 

OFF-state leakage current: less than 10 µA

 

 

ON-state saturation voltage: less than 1V at 10 mA and less than 1.5V at 100 mA

 

 

Analog Output:

 

 

Voltage sourcing: 0 to 10V dc (at 1 kΩ min. resistance)

 

 

Current sourcing: 4 to 20 mA, 1 Ω to Rmax.

 

 

Rmax = Vsupply - 7V

 

 

 

20 mA

 

 

 

 

 

 

 

Output Response Time

Discrete output: “A” suffix models: 48 milliseconds

 

 

“B” suffix models: 96 milliseconds

 

 

Analog output: “A” suffix models: 48 milliseconds average, 16-millisecond update

 

 

“B” suffix models: 96 milliseconds average, 32-millisecond update

 

 

 

 

 

 

Teflon® is a registered trademark of Dupont™.

More on

next page

 

 

 

 

274 More information online at bannerengineering.com

Page 32
Image 32
Banner L-GAGE manual T30U, 15-24V dc, GAGET30U Specifications