Banner L-GAGE U-GAGE T18U Specifications, cont’d, Measurement & Inspection, Emitter Models MI20 p

Models: L-GAGE

1 66
Download 66 pages 29.94 Kb
Page 44
Image 44
U-GAGE®T18U Specifications

LIGHT GAUGING

LABEL&

 

ULTRASONIC

 

SLOT

 

LIGHT

 

lUMINESCENCE

MEASURING

 

 

SCREENS

&

 

COLOR

 

TEMPERATURE

 

LIGHT-TO-

 

PICK

 

RADAR

 

MEASUREMENT & INSPECTION

 

U-GAGE®T18U Specifications

(cont’d)

Output Response Time

NORMAL resolution mode: 2 milliseconds ON/OFF

 

 

HIGH resolution mode: 1 millisecond ON/OFF

 

 

 

 

Rep Rate

NORMAL resolution mode: 125 Hz max.

 

 

HIGH resolution mode: 200 Hz max.

 

 

 

 

 

Mechanical Sensing

NORMAL resolution mode: less than 2 mm

 

Repeatability at

 

HIGH resolution mode: less than 1 mm

 

300 mm range

 

 

 

 

 

 

 

 

Beam Angle

15 ± 2˚

 

 

(-3dB full angle)

 

 

 

 

 

 

 

Indicators

Emitters have a green LED for dc power ON. Receivers have two LED’s, one yellow and one green.

 

Indications are as follows:

 

 

 

Green ON steady: dc power ON

 

 

Green flashing: output overloaded

 

 

Yellow flashing: sonic signal received (flash rate is proportional to received signal strength;

 

flash is from full to half intensity).

 

 

 

Construction

T-style yellow PBT polyester housing with black PBT polyester back cover. Transducer housing is

 

threaded M18 x 1. Mating jam nut is supplied for mounting. Acoustic face is epoxy reinforced. Circuitry

 

is epoxy-encapsulated.

 

 

 

 

 

 

Environmental Rating

IEC IP67; NEMA 6P

 

 

 

 

Connections

Emitters: 2 m long attached PVC- covered 2-wire cable or 4-pin Euro-style quick-disconnect fitting.

 

Receivers: 2 m long attached PVC-covered 4-wire cable or 4-pin Euro-style quick-disconnect fitting.

 

9 m long cables are available by request.

 

 

Mating Euro-style quick-disconnect cables are also available. See page 412.

 

 

 

 

Operating Temperature

-40° to +70° C

 

 

 

 

 

 

Vibration and

Meets Mil.Std 202F requirements.

 

 

Mechanical Shock

Method 201A (Vibration: frequency 10 to 60 Hz, max., and double amplitude 0.06-inch,

 

maximum acceleration 10G).

 

 

 

Method 213B conditions H&I (Shock: 75G with unit operation; 100G for non-operation)

 

Also meets IEC 947-5-2 requirements: 30G, 11 milliseconds duration, half sine wave.

 

 

 

 

Certifications

 

 

 

 

 

 

 

Hookup Diagrams

Emitter Models: MI20 (p. 536)

NPN Models: MI18 (p. 536)

PNP Models: MI19 (p. 536)

 

 

 

 

286 More information online at bannerengineering.com

Page 44
Image 44
Banner L-GAGE U-GAGE T18U Specifications, cont’d, Measurement & Inspection, NORMAL resolution mode 2 milliseconds ON/OFF