U-GAGE®T30U Specifications (cont’d)

MEASUREMENT & INSPECTION

 

U-GAGE®T30U Specifications (cont’d)

Sensing Performance

Analog sensing resolution or discrete output repeatability: ±0.25% of measured distance

(Specified using a 100 x

“A” suffix models: .5 mm min

 

100 mm aluminum target at

“B” suffix models: 1 mm min

 

25˚ C under fixed sensing

Analog linearity: ±0.5% of full-scale span

conditions.)

Min. window size: 10 mm

 

 

Hysteresis of discrete output: 2.5 mm

 

Temperature effect: 0.2% of sensing distance per ° C

 

 

Adjustments

Sensing window limits (analog or discrete): TEACH-mode programming of near and far window

 

limits may be set using membrane push buttons on sensor or remotely using TEACH input. Window

 

limits may be programmed separately, or together.

 

Analog output slope: the first limit taught is assigned to the minimum output value (4 mA or 0V).

 

 

 

Indicators

Four status LEDs: In RUN mode:

 

 

Green ON Steady: Power ON, RUN mode

 

Green Flashing: Discrete output is overloaded

 

Red Flashing: Relative received signal strength

 

Yellow analog ON Steady: Target is inside window limits

 

Yellow discrete ON Steady: Output conducting

 

In Program mode:

 

 

Green OFF: PROGRAM mode

 

Red Flashing: Relative received signal strength

 

Yellow ON Steady: Ready for first window limit

 

Yellow Flashing: Ready for second limit

 

Yellow OFF: Not teaching this output

 

 

Construction

Molded reinforced thermoplastic polyester housing.

 

 

Environmental Rating

Leakproof design is rated IEC IP67; NEMA 6P

 

 

Connections

2 m or 9 m 5-conductor PVC-covered attached cable, or 5-pin Euro-style quick-disconnect fitting.

 

QD cables are ordered separately. See page 415.

Operating Conditions

Temperature: -20° to +70° C

Relative humidity: 100%

 

 

Vibration and

All models meet Mil. Std. 202F requirements. Method 201A (Vibration: 10 to 60Hz max., double

Mechanical Shock

amplitude 0.06", maximum acceleration 10G). Also meets IEC 947-5-2 requirements: 30G, 11

 

milliseconds duration, half sine wave.

 

Application Notes

Objects passing inside the specified near limit will produce a false response.

 

NOTE: For more information about out-of-range and signal loss response of the analog output,

 

see product literature.

 

 

 

 

Certifications

 

 

 

 

Hookup Diagrams

Analog/Discrete Models: MI16 (p. 535)

 

Dual-Discrete Models: MI15 (p. 535)

 

 

 

 

LIGHT ULTRASONIC MEASURING LIGHT TEMPERATURE RADAR GAUGINGSCREENS

More information online at bannerengineering.com

275

Page 33
Image 33
Banner L-GAGE U-GAGE T30U Specifications cont’d, Measurement & Inspection, Specified using a 100, mm aluminum target at