L-GAGE®LT7 Specifications

Sensing Range

LT7PLVQ: 0.5 to 250 m (using specified reflector)

 

LT7PIDQ: 6% Black card: 0.5 to 3 m

 

 

18% Gray card: 0.5 to 7 m

 

 

90% White card: 0.5 to 10 m

 

 

 

 

 

Supply Voltage and

18 to 30V dc (10% max. ripple)

 

Current

 

 

 

 

Power Consumption

Less than 4.5 W @ 25º C

 

 

 

 

Measuring Laser

Infrared, 900 nm, Class 1

 

 

 

Laser Control

Measurement laser is ON when sensor is ON. Pilot (visible) laser enabled during Programming mode;

 

alternates with measurement laser.

 

 

 

 

 

Spot Size

LT7PLVQ:

Distance

Spot Size

 

10 m

ø 20 mm

 

 

50 m

ø 100 mm

 

 

100 m

ø 200 mm

 

 

250 m

ø 500 mm

 

LT7PIDQ:

4 m

3 x 10 mm

 

 

6 m

4 x 12 mm

 

 

10 m

10 x 20 mm

 

 

 

Pilot Laser (Alignment)

Visible red, 650 nm, Class 2

 

 

 

 

 

Discrete & Analog

Protected against continuous overload and short circuit

Output Protection

 

 

 

Discrete Outputs

(2) 100 mA, PNP

 

 

 

 

 

Discrete Switch Points

Adjustable in 1 mm steps

 

 

 

 

 

Discrete Output

Adjustable, 10 mm min.

 

Hysteresis

 

 

 

 

Alarm Outputs

50 mA, PNP (NO)

 

 

 

 

 

 

Analog Output

LT7PLVQ: None

 

 

 

LT7PIDQ: 4-20 mA

 

 

 

 

 

 

Maximum Cable Length

100 m

 

 

 

 

 

 

Output Response Time

12 milliseconds

 

 

 

 

 

 

Linearity

±10 mm

 

 

 

 

 

 

Resolution/Repeatability

LT7PLVQ: ±2 mm

 

 

 

LT7PIDQ: ±4 mm

 

 

Color Sensitivity

LT7PLVQ: Not Applicable

 

 

LT7PIDQ: Contact Factory

 

 

 

Temperature Effect

Less than ± 5 mm over the total sensing range

 

 

 

Minimum Analog

LT7PLVQ: Not Applicable

 

Window Size

LT7PIDQ: 300 mm

 

 

Adjustments

Push-button-directed password enable/disable, measurement unit select, offset value select, output

 

limits set, output mode select, analog output slope select (diffuse models only) and output limit manual

 

adjust. See data sheet for information.

 

 

 

 

Serial Interface

RS-422 or SSI compatible

 

 

 

Serial Measurement Speed

SSI: 1.4 milliseconds (SSI cycle 80 microseconds) RS-422:2.9 milliseconds @ 57.6 kBaud

 

 

 

 

 

 

 