154 DX-700 • User’s Guide • Rev 02
4. Operation
DX-700 Management Menu Operations
Use the following steps to set the genlock source for the outputs in a bank:
1. From the Home Menu, press {DX-700 Management}.
2. Press {Genlock} to display the Bank Sync Menu.
Figure 4-92. Bank Sync Menu (sample)
Below the menu title, the Source Frame Rate field shows the DX-700’s currently
selected sync source frame rate. This value changes dynamically when you
select different sources and/or frame rates.
3. In the Sync Source section, select the radio button for the desired genlock
source. Three options are available:
~If Freerun is selected, the system immediately locks to the DX-700’s
internal timing generator, and the Freerun Rate section is activated.
Select a freerun frame rate using the radio buttons in the
Freerun Rate section (50, 59.94, or 60), or set a custom rate.
Please continue with step 6.
~If Input is selected, focus jumps to one of your input modules.
Select an input module and an associated input connector.
Please continue with step 4.
~If Master Sync is selected, the bank locks to the master sync source.
You set this source by pressing {Master} and using the Master Sync
Menu. Refer to the “Setting the Master Sync Source” section on
page156 for instructi ons.