40 DX-700 • User’s Guide • Rev 02
2. Hardware Orientation
DX-700 Rear Panel
auJTMM=oÉ~ê=m~åÉä
The figure below illustrates the DX-700 rear panel:
Figure 2-1. DX-700 Rear Panel, with sample DVI I/O configuration
Following are descriptions of each rear panel connector:
1) Input / Output Section
The Input / Output Section provides seven slots for both input and output
modules, which can be arranged in a variety of configurations and “banks.” Each
module is fully shielded and field-installable.
~A single “universal” input module is available. Refer to the “Input
Module” section on page41 for details.
~Two different output modules are available (DVI and NNI). Refer to the
Output Modules” section on page 45 for details.
~Refer to the “Input Module” section on page41 for important rules
governing the configuration and placement of modules.
2) System Module
The System Module is standard on all DX-700 units. It provides connections for
synchronization, monitoring, control and diagnostics. Refer to the “System
Module” section on page51 for details.

1 2 3

EXP OUT DVI / EXP IN
RGBHV
1 - HD/SDI - 2
Y / COMP C / Pb Pr
EXP OUT DVI / EXP IN
RGBHV
1 - HD/SDI - 2
Y / COMP C / Pb Pr
EXP OUT DVI / EXP IN
RGBHV
1 - HD/SDI - 2
Y / COMP C / Pb Pr
LED OUT 1 LED OUT 2 LED OUT 3
100-240V
50-60 Hz, 5.0 A
DIAGNOSTICETHERNETDMX THRUDMX IN
V INH / CS IN LOCK MONITOR
GENLOCK EXP
1) Input / Output Section 3) Power Supply
2) System Module