64 DX-700 • User’s Guide • Rev 02
3. Installation
Power Installation
mçïÉê=`çêÇLiáåÉ=sçäí~ÖÉ=pÉäÉÅíáçå
DX-700 is rated to operate with the following specifications:
Input Power: 100-240 VAC, 50-60 Hz
Power Consumption: 500 watts maximum
DX-700 performs line voltage selection automatically, and no user controls are required.
The AC power cords must be accessible so that they can be removed during field servicing.
Figure 3-1. Tandem Prong-type Plug
Warning When the DX-700 is used in the 230-volt mode, a UL listed
line cord rated for 250 volts at 15 amps must be used and
must conform to IEC-227 and IEC-245 standards. This cord
will be fitted with a tandem prong-type plug.
The rear panel ON/OFF switch does not disconnect the unit
from input AC power. To facilitate disconnection of AC
power, the power cord must be connected to an accessible
outlet near the unit.
Building Branch Circuit Protection: For 115 V use 20 A, for
230 V use 8 A.
Avertissement La choix de la ligne de voltage se réalise automatiquement
par le DX-700 Transformateur Graphique. On n'a pas besoin
du controller usager pour la choix de la ligne de voltage.
Warnung Das DX-700 gerät mu beim Anschlu an 240V ~ mit einer vom
VDE auf 250V/10A geprüften Netzleitung mit einem
Schukostecker ausgestattet sein.