DX-700 • User’s Guide • Rev 02 159
4. Operation
DX-700 Management Menu Operations
mêÉJëÉäÉÅíáåÖ==íÜÉ=aÉä~ó=jçÇÉ
The Reduced/Minimum Delay Menu enables you to “pre-select” one of three delay
modes that will be implemented when you run the Setup Wizard and Input Wizard. In
Chapter1, refer to the “DX-700 Video Processing Delay” section on page 28 for a
complete explanation of all three modes.
Use the following procedure to pre-select the delay mode.
1. From the Home Menu, press {DX-700 Management}.
2. Press {Expert} to display the Expert Menu.
3. Press {Reduced/Minimum Delay} to display the Reduced/Minimum Delay
Menu.
Figure 4-96. Reduced/Minimum Delay Menu
4. Select the radio button for the desired mode:
~Select Standard Mode for very large LED walls. Delay will be 80ms for
interlaced sources and 40-60ms for progressive sources.
~Select Reduced Delay Mode for most applications. This mode creates
no processing artifacts and is best suited for live events. Delay will be
23ms for interlaced sources and 2ms for progressive sources.
~Select Minimum Delay Mode when you require the absolute minimum
delay, and you are willing to forego some quality. The mode is very
good for content that contains low details. Delay will be 2ms for
interlaced sources and 2ms for progressive sources.
Remember that this is a “pre-select” only. The mode will not take effect until both
the Setup Wizard and Input Wizard are run.
5. Press {Previous} to return to the Expert Menu, or press {Home} to return to the
Home Menu.