Barco R9002120 manual Common Settings, Service Mode, G2 Adjustment, CRT run in cycle

Models: R9002120

1 57
Download 57 pages 45.14 Kb
Page 47
Image 47
Common Settings

Service Mode

Common Settings

Highlight 'Common settings' by pushing the control disk up or down and press ENTER to display the common settings menu.

Within the common settings menu, the following items can be set up or executed :

-G2 adjustment

-CRT run in cycle

-Projector warm up

G2 Adjustment

Item is password protected.

Highlight 'G2 adjust' with the control disk and press ENTER to continue.

A safety notice will be displayed on the screen as it is necessary to open the top cover to adjust the G2.

ENTER selects the G2 adjustment.

EXIT returns to the Common settings menu.

ADJUST returns to the Operational mode.

'G2 adjustment should be performed by BARCO personnel, or BARCO authorized dealers'.

If you are qualified, press ENTER to continue. If not qualified, press EXIT to return to the Common settings menu. Further description of the G2 adjustment is given in the Installation manual.

CRT run in cycle

The CRT run in cycle option can only be activated when memory blocks on an internal # pattern are available. When one or more such blocks are available, a flashing white image (5sec on, 5 sec off) is generated and that for 5 min on the first internal block. In the next 5 min, a second internal block will be used to generate the flashing white image. The image will also be shifted in a vertical way to prevent a CRT burn in. To quit the CRT run in cycle option, press EXIT.

Highlight 'CRT run in cycle' with the control disk and press ENTER to start.

ENTER selects the CRT run in cycle option.

EXIT returns to the Path Selection main menu.

SERVICE MODE

PROJECTOR SET-UP

MEMORY MANAGEMENT

COMMON SETTINGS

I2C DIAGNOSTICS

Select with G2 Adjustment or then <ENTER> <EXIT> to return.

COMMON SETTINGS

G2 ADJUSTMENT

CRT RUN IN CYCLE

PROJECTOR WARM UP

Select with

or

then <ENTER>

<EXIT> to return.

COMMON SETTINGS

G2 ADJUSTMENT

CRT RUN IN CYCLE

PROJECTOR WARM UP

CRT DRIVE MODE

Select with

or

then <ENTER>

<EXIT> to return.

SAFETY

NOTICE

RISK OF ELECTRICAL SHOCK

G2 ADJUSTMENT SHOULD BE

PERFORMED

BY BARCO PERSONNEL,

OR BARCO AUTHORIZED

DEALERS.

IF QUALIFIED, PRESS <ENTER> TO CONTINUE, OR IF NOT, <EXIT> TO RETURN.

COMMON SETTINGS

G2 ADJUSTMENT

CRT RUN IN CYCLE

PROJECTOR WARM UP

CRT DRIVE MODE

Select with

or

then <ENTER>

<EXIT> to return.

5975977 BARCODATA 708 260597

 

7 - 9

 

Page 47
Image 47
Barco R9002120 manual Common Settings, Service Mode, G2 Adjustment, CRT run in cycle