78 en Interfaces

Camera Browser Interface

 

 

13 Interfaces

13.1Alarm input

Configure the alarm triggers for the camera.

Select N.C. (Normally Closed) if the alarm is to be triggered by closing the contact.

Select N.O. (Normally Open) if the alarm is to be triggered by opening the contact.

13.1.1Name

Enter a name for the alarm input. This is then displayed below the icon for the alarm input on the LIVEPAGE (if configured).

13.2Relay

Configure the switching behavior of the relay output.

Select different events that automatically activate an output. For example, turn on a floodlight by triggering a motion alarm and then turn the light off again when the alarm has stopped.

13.2.1Idle state

Select Open for the relay to operate as an N.O. contact, or select Closed if the relay is to operate as an N.C. contact.

13.2.2Operating mode

Select the way the relay works.

13.2.3Relay follows

Select the event that triggers the relay.

13.2.4Relay name

The relay can be assigned a name here. The name is shown on the button next to Trigger relay. The LIVEPAGE can also be configured to display the name next to the relay icon.

13.2.5Trigger relay

Click the button to switch the relay manually (for example, for testing purposes or to operate a door opener).