Bosch Appliances FW5.50 11.3Audio Alarm, 11.3.1Audio alarm, 11.3.2Name, 11.3.3Signal Ranges

Models: FW5.50

1 94
Download 94 pages 45.97 Kb
Page 65
Image 65
11.3Audio Alarm

Camera Browser Interface

Alarm en 65

 

 

11.3Audio Alarm

Alarms can be generated based on audio signals. Configure signal strengths and frequency ranges so that false alarms, for example, machine noise or background noise, are avoided. Set up normal audio transmission before configuring the audio alarm.

11.3.1Audio alarm

Select On for the device to generate audio alarms.

11.3.2Name

The name makes it easier to identify the alarm in extensive video monitoring systems, for example with the Bosch Video Client and the Bosch Video Management System. Enter a unique and clear name here.

11.3.3Signal Ranges

Exclude particular signal ranges in order to avoid false alarms. For this reason the total signal is divided into 13 tonal ranges (mel scale). Check or uncheck the boxes below the graphic to include or exclude individual ranges.

11.3.4Threshold

Set up the threshold on the basis of the signal visible in the graphic Set the threshold using the slide control or, alternatively, move the white line directly in the graphic using the mouse.

11.3.5Sensitivity

Use this setting to adapt the sensitivity to the sound environment and effectively suppress individual signal peaks. A high value represents a high level of sensitivity.