Sequence Programming

Continue entering camera, monitor, and dwell times in this fashion until finished. If you only want to store the sequence for future use and then exit the programming mode, press Exit / Save [Prog]. Press Exit / Run [Run], to exit the programming mode, store the sequence into memory, and start the sequence running. The switcher steps through the five (5) steps in the order shown, and repeats the sequence when it reaches the last step.

To program a sequence to run once through all its steps and then stop, enter the value 62 for the dwell time in the last step and press [Enter]. The dwell display will change to STP, meaning stop. To program a sequence to run once through all its steps and then unload itself, enter the value 63 for the dwell time in the last step, and press [Enter]. The dwell display will change to ULD, meaning unload.

To edit an existing sequence, press Program Sequence [Prog], enter the existing sequence number, then press [Enter]. You can insert a line into a sequence by navi- gating down to the line where inserting a new line, and press Insert Step [ON]. A new line identical to the one you are on is added to the next step. To delete a step, navigate to the line to be deleted, and press Delete Current Step [OFF]. To delete all steps below the line you are viewing, press Delete From Here To End [Lock]. (Be careful with this feature!)

It is also possible to erase a sequence: Press Delete From Here To End [Lock] while on the first line of the sequence. Then press Delete Current Step [OFF]. The sequence will be erased, and the programming mode is automatically exited.

Sequence Function Summary

All programming key functions for the LTC 8555 Series are summarized in the fol- lowing table:

Key

Description

 

 

PROG

Selects or terminates program mode

 

 

CLEAR

Clears current entry

 

 

ENTER

Stores current entry

 

 

PREV

Stores entry and move up one step

 

 

NEXT

Stores entry and move down one step; add new

 

step if necessary

 

 

ON

Insert step before current step

 

 

OFF

Delete current step

 

 

UP

Move up one step

 

 

DOWN

Move down one step, if step already exists

 

 

LEFT

Move prompt left one cell

 

 

RIGHT

Move prompt right one cell

 

 

LOCK

Erase all steps after current step

 

 

RUN

Exit, store, load, and run current sequence

 

 

EN 51

Page 61
Image 61
Bosch Appliances 8500, LTC instruction manual Sequence Function Summary, Sequence Programming, Key Description