Bosch Appliances LTC, 8500 instruction manual Error 71 - Step monitor required

Models: 8500 LTC

1 104
Download 104 pages 32.59 Kb
Page 82
Image 82

Error 70 - Monitor not allocated to alarm monitor group

This monitor can not be used for alarm operations; it has not been designated as alarm-capable by the system programmer.

Error 71 - Step monitor required

A group of alarm monitors may not have an armed Review (display) monitor without having armed Step (sequence) monitors.

Error 78 - Must enter alarm number

A specific alarm number must be entered when arming or disarming an alarm.

Error 80 - Trunk not available

An attempt was made to access a remote camera connected to a satellite system, but no unused trunk lines are currently available. Depending on system config- uration and certain user options, the operator's monitor may automatically switch to the default camera programmed into the Start-up column of the Moni- tor Table when this error occurs.

Error 81 - Satellite Trunk Seized

The camera currently viewed has changed because an operator with a higher priority has selected a different camera that seized the trunk line from the satel- lite. The operator's monitor will automatically be switched to the default camera programmed into the Start-up column of the Monitor Table.

Error 89 - internal stack error

A stack overflow within the system has occurred. Report this to the manufac- turer.

Error 90 - Keyboard entry undefined

The keyboard entry is not defined. Check the appropriate section of the instruc- tion manual for the desired operation and try again.

Error 92 - Keyboard entry out of range

The data entered for a valid command was not in the range allowed by the sys- tem. Check the appropriate section of the instruction manual for the acceptable ranges for the command in question and try again.

Error 94 - Keyboard entry invalid

An invalid character has been received from the keyboard. Usually this would indicate a communications error. Verify that the keyboard-to-system cable is not producing an intermittent connection.

Error 95 - Keyboard entry incomplete

The control sequence sent from the keyboard was incomplete. Usually this would indicate a communications error. Verify that the keyboard-to-system cable is not producing an intermittent connection.

Error 96 - * (STAR) undefined

The * key has been pressed, but there is no definition for this button.

EN 72

Bosch Security Systems December 13, 2005

Page 82
Image 82
Bosch Appliances LTC, 8500 instruction manual Error 71 - Step monitor required