13 Factory Default Settings

User Selectable DIP Switch Settings for Main CPU Bay

13 Factory Default Settings

As the Allegiant system is shipped from the factory, certain features are placed in a default configuration. The installer can select some of these features at the time of system installation/configuration. Generally the default configuration represents the simplest mode of operation, allowing the user to become familiar with the system before any advanced features are selected. The default settings are described in the sections below.

13.1 User Selectable DIP Switch Settings for Main CPU Bay

NOTE

After changing any of the following switches, the system must either be pow-

 

ered OFF and ON or reset using the keyboard (see User Function 15).

Upper CPU DIP Switch S1001

System CPU modules contain two (2) 8-position DIP switches. The settings of the upper DIP switch do not need to be changed from their factory default positions except when using a Console Port Expander accessory unit or if a problem is encountered when downloading new firmware into the CPU. For reference, the functions are as follows:

DIP Switch

Factory Default

“Upper” S1001 DIP Switch Function

Number

Setting

 

 

 

 

1

OFF

Not Used

 

 

 

2

OFF

Not Used

 

 

 

3

OFF

Console Expander Use

 

 

 

4

OFF

Console Expander Mode

 

 

 

5

OFF

Boot Mode

 

 

 

6

OFF

Boot Mode Handshake

 

 

 

7

OFF

Boot Mode Baud Rate

 

 

 

8

OFF

Boot Mode Baud Rate

 

 

 

Switch 1 and 2 of S1001

These switches are not used in these systems and should be left OFF.

Switch 3 of S1001

This switch should be set to ON if an LTC 8712 Series Console Port Expander is connected to the Allegiant’s console port. This selection can also be set using either the MCS or the PC-based GUI Software package.

Switch 4 of S1001

This switch is used to set the communication baud rate which the Allegiant will use when connected to a LTC 8712 Series Console Port Expander. It is only applicable when DIP switch 3 is in the ON position. When set to ON, the baud rate will be 57,600 bps (recommended setting). When OFF, the baud rate fol- lows the setting determined via DIP switch 8 of the lower CPU DIP switch. If switch 8 of the lower DIP switch is OFF, the baud rate defaults to 19,200 bps. If switch 8 of the lower DIP switch is ON, the user programmed baud setting is used, but the user setting must be 19,200 baud or higher in order to operate.