7.6.4Calibration
Calibration is a function for automatically correcting an error on the angle of Pan/Tilt. Calibration can be set at Auto or Manual. In Auto mode, the camera is corrected automatically whenever there is an error on the angle of the camera. The motor of the Pan/Tilt will adjust its angle automatically. In Manual mode, select the option "Calibration" to execute the function.
Error Message Display is a function for displaying an error message to let a user know when there is an error.
1.From the MAIN MENU, select DOME MOTION. The submenu DOME MOTION appears.
2.Select CALIBRATION. The screen CALIBRATION SETUP appears.
CALIBRATION SETUP
AUTO CAL
ERROR MSG DISP
CALIBRATION
SAVE
BACK
3.Select the option "Auto Cal". This function is for automatic calibration.
4.Select the appropriate value: AUTO or MANUAL.
5.In Manual mode, select the option "Calibration" to execute the function using the joystick.
6.Select the option "Yes" or press the [Near] button to continue.
7.Select the option "Error Msg Disp" (Error Message Display).
8.Select the appropriate option: ON or OFF.
9.Save the settings.
Bosch Security Systems, Inc. | User Manual | F.01U.252.635 2.0 2011.09 |