56 en On-Screen Display (OSD) Menu

VEZ-400 Mini PTZ Dome

 

 

13.Select the option "DTime" to set the dwell time for the scan.

14.Set the desired time (from 3 minute to 60 seconds).

15.Select the option "Direction."

16.Select the appropriate value for the direction of the scan.

17.Select the option "Mode."

18.Select the appropriate value for the mode. In Auto Scan there are two modes:

Endless mode: When the Start Position is the same as the Stop Position, the dome moves around.

Coming/Going mode: When the Start Position is different from the Stop Position, the dome moves repeatedly from one position to another.

19.Save the settings.

Note: Select the option "Clear" to delete the scan.

In order to call an action (Preset, Pattern, Tour, or Scan), you must save Preset, Pattern, Tour, or Scan first.

– You can also edit the Scan title. Select the option "Title," then edit the title following the steps in

Section 7.2.1 Editing Titles, page 32.

7.11Alarm Setup

This menu controls alarm inputs and outputs. To set alarms:

1.From the MAIN MENU, select ALARM SETUP. The screen ALARM SETUP appears.

2.Select the option "NO.###" to select a preset number.

ALARM SETUP

NO.

IN

OUT

PRIORITY

ACTION

NUMBER

ATIME

SAVE

F.01U.252.635 2.0 2011.09