Bosch Appliances VG5 600 user manual Bist

Models: VG5 600

1 74
Download 74 pages 14.45 Kb
Page 24
Image 24

24 en On-Screen Display Menu NavigationAutoDome 600 Series Analog PTZ Camera

Menu

Description

Sub-menu / Description

 

 

 

 

Exit

Saves and exits the menu.

 

 

 

 

 

Alarm Status

Enters the Alarm Status menu and displays the

Alarm Inputs 1 to 7, Alarm Outputs 1

 

real time status of alarm inputs and outputs.

to 3 and Alarm Relay

 

 

 

BIST

Enters the Perform Built-in Self Tests menu. If

YES to start test. NO to exit the

 

confirmed, the BIST tests start and the results

menu.

 

 

are displayed.

Typical results displayed as follows:

 

 

BIST

 

 

 

Exit...

 

 

 

Data Flash:

PASS

 

 

Bilinx:

PASS

 

 

FPGA:

PASS

 

 

Digital I/O 1:

PASS

 

 

Digital I/O2:

PASS

 

 

VCA:

PASS

 

 

Homing:

PASS

 

 

 

 

Internal Temp.

Displays the current dome temperature.

 

 

 

 

 

 

High Temp Events

Displays the number of times the high

 

 

 

temperature threshold is exceeded.

 

 

 

 

 

 

Highest Temp

Displays the highest temperature reached.

 

 

 

 

 

 

Low Temp Events

Displays the number of times the low

 

 

 

temperature threshold is exceeded.

 

 

 

 

 

 

Lowest Temp

Displays the lowest temperature reached.

 

 

 

 

 

 

Security Access

Displays the number of times the locked-

 

 

 

command menu is unlocked.

 

 

 

 

 

 

CTFID Access

Displays the number of times the Configuration

 

 

 

Tool is accessed.

 

 

 

 

 

 

Homing Events

Displays the number of times the AutoDome was

 

 

 

rebooted.

 

 

 

 

 

 

Homing Failed

Displays the number of times the AutoDome

 

 

 

failed to home properly.

 

 

 

 

 

 

Loss Home Events:

Displays the number of times the AutoDome lost

 

 

 

the home position.

 

 

 

 

 

 

Home Position Good

Displays if the current AutoDome home position

 

 

 

is good. Displays YES if good.

 

 

 

 

 

 

Restart Events

Displays the number of restart events.

 

 

 

 

 

 

Low Volt Events

Displays the number of times the AutoDome

 

 

 

dropped below the acceptable voltage limit.

 

 

 

 

 

 

Power Up Events

Displays the number of power up events.

 

 

 

 

 

 

Video Loss Events

Displays the number of time that video was lost.

 

 

 

 

 

 

F.01U.270.005 2.0 2012.06

User Manual

Bosch Security Systems, Inc.

Page 24
Image 24
Bosch Appliances VG5 600 user manual Bist