56 en Troubleshooting GuideAutoDome 600 Series Analog PTZ Camera

No camera control

Ensure that the keyboard and monitor are set to the correct (same) camera number.

 

If O.K., then:

 

– Check that the camera address is properly set. Enter ON-997-ENTERto display the

 

 

camera address.

 

If address is not set or is incorrect, then:

 

– Set the camera address using FastAddress (ON-998-ENTER).

 

If O.K., then:

 

– Check that the Amber LED on the AutoDome CPU turns on when receiving pan/tilt

 

 

commands from the controller keyboard. The Amber LED indicates control is being

 

 

received.

 

Amber LED on AutoDome CPU Module

 

Flash Sequence

 

Off

 

 

No incoming communications or no power

 

– Solid for 2 seconds

 

 

Receiving good data

 

Fast blinking

 

 

Lost packet(s)

 

If amber LED does not light when given PTZ commands, then:

 

– Check if other cameras on the system can be controlled. If not, check the controller

 

 

and wiring connections.

 

If O.K., then:

 

– Check that the RS-232/485 selector switch is properly set to the proper protocol.

 

If O.K., then:

 

– Ensure that all Biphase, Bilinx, or RS-232/485 wires are properly connected. See the

 

 

VG5 AutoDome Installation Manual.

 

If O.K., then:

 

– Check if you can access the AutoDome OSD menus (ON-46-ENTER).

 

If O.K., then:

 

– Confirm that the AutoDome passes homing (SET-110-ENTER).

 

If AutoDome fails homing, then:

 

– Contact Bosch Technical Support.

 

 

 

Intermittent camera

Check that only the last AutoDome in a daisy chain configuration is terminated with a

control

 

100 Ω resistor across the +/- biphase terminals.

 

If O.K., then:

 

– Check that the maximum wire distance has not been exceeded for the control protocol

 

 

(the maximum distance for RS-232 is 50 feet). See the VG5 AutoDome Installation

 

 

Manual.

 

If O.K., then:

 

– Check that all wiring meets Bosch recommended standards and specifications. See the

 

 

VG5 AutoDome Installation Manual.

 

 

 

Camera moves when

Check that the camera address is properly set (ON-997-ENTER). If the camera address

moving other

 

is not set, the AutoDome responds to control commands to any camera on the system.

cameras

If camera address is not set, then:

 

– Invoke the FastAddress Menu to assign a camera address (ON-998-ENTER).

 

 

 

Cannot access user

Enter the unlock command OFF-90-ENTER. This command may require a password.

settings

 

(Commands automatically lock in 30 minutes.)

 

 

 

F.01U.270.005 2.0 2012.06

User Manual

Bosch Security Systems, Inc.

Page 56
Image 56