58 en Troubleshooting GuideAutoDome 600 Series Analog PTZ Camera

Inside of Outdoor

– Check the status of the Heater Module (ON-66-ENTER).

Pendant bubble is

If status reports Heater No Power, then:

foggy

– Turn off the power to the AutoDome.

 

– Check the FX103 fuse in the Power Supply Box for power (24 V) to the heater module.

 

If O.K., then:

 

– Check all wiring and connector pins to the heater module.

 

 

Low Voltage flashing

– If using a non-Bosch power supply, confirm that it meets the Bosch AutoDome power

on monitor display

ratings. See the AutoDome Datasheet for specifications.

 

If O.K., then:

 

– Check the mains input line voltage.

 

If O.K., then:

 

– Check that the maximum wire length from the power supply has not been exceeded.

 

See the VG5 AutoDome Installation Manual.

 

If O.K., then:

 

– Measure the AC voltage input to the camera while power is applied to the camera. The

 

voltage must be ≥ 21 VAC to stop the message.

 

 

F.01U.270.005 2.0 2012.06

User Manual

Bosch Security Systems, Inc.

Page 58
Image 58
Bosch Appliances VG5 600 user manual Inside of Outdoor, Low Voltage flashing, On monitor display