58 en | Troubleshooting Guide AutoDome 600 Series Analog PTZ Camera
F.01U.270.005 | 2.0 | 2012.06 User Manual Bosch Security Systems, Inc.
Inside of Outdoor
Pendant bubble is
foggy
Check the status of the Heater Module (ON-66-ENTER).
If status reports Heater No Power, then:
Turn off the power to the AutoDome.
Check the FX103 fuse in the Power Supply Box for power (24 V) to the heater module.
If O.K., then:
Check all wiring and connector pins to the heater module.
Low Voltage flashing
on monitor display
If using a non-Bosch power supply, confirm that it meets the Bosch AutoDome power
ratings. See the AutoDome Datasheet for specifications.
If O.K., then:
Check the mains input line voltage.
If O.K., then:
Check that the maximum wire length from the power supply has not been exceeded.
See the VG5 AutoDome Installation Manual.
If O.K., then:
Measure the AC voltage input to the camera while power is applied to the camera. The
voltage must be ≥ 21 VAC to stop the message.