AutoDome 600 Series Analog PTZ CameraAlternative Control Protocols en 29

4

Alternative Control Protocols

The VG5 AutoDome supports three alternative control protocols that allow a user to send commands and to receive information from the AutoDome. The VG5 AutoDome supports the following protocols:

Pelco-P

Pelco-D

American Dynamics (AD) Manchester

American Dynamics (AD) Sensormatic RS-422

The VG5 AutoDome natively supports the two Pelco protocols. To use the AD Manchester or the AD Sensormatic RS-422 protocol you must purchase a separate module. The module contains instructions to install any additional hardware and information about additional on- screen menus.

4.1

Setting FastAddress with Alternative Protocols

 

The VG5 AutoDome offers remote addressing via the FastAddress capability from a keyboard

 

that uses an alternative protocol. The FastAddress feature allows you to instal all domes first,

 

then set the addresses via the control system. Since it is not necessary to go to the camera’s

 

physical location, this feature makes it easier to readdress cameras at a later time.

4.1.1

Using an American Dynamics Controller

 

Prior to setting the FastAddress for each camera, all cameras will initially move together. After

 

the Unique Identifier is set, only the camera that was set with the FastAddress is capable of

sending and receiving commands. When setting the FastAddress, it is important to remember that some American Dynamics Manchester systems use address blocks of 1 to 64, while American Dynamics Sensormatic systems typically use address blocks of 1 to 99; meaning that when the controller/keyboard displays video for cameras higher than 64 or 99 the keyboard/controller sends a different control code to the camera (see Section A Appendix: FastAddress Conversions, page 64, for conversion charts). For example at Camera 65, the American Dynamics Manchester system sends out an address of 1, while the Sensormatic RS- 422 system with an address of 100 also sends out an address of 1.

It is NOT NECESSARY to convert these numbers with the Bosch FastAddress method. The camera automatically detects the address being transmitted by the Sensormatic RS-422 control system and adjusts the camera accordingly.

Bosch Security Systems, Inc.

User Manual

F.01U.270.005 2.0 2012.06

Page 29
Image 29
Bosch Appliances VG5 600 user manual Alternative Control Protocols, Setting FastAddress with Alternative Protocols