AutoDome 600 Series Analog PTZ CameraAlternative Control Protocols en 33

8. Move the joystick down then back up to set the FastAddress number.

9. Press the FOCUS or the IRIS button to store the FastAddress number.

The on-screen display menu confirms that the VG4 AutoDome stored the FastAddress number.

4.2

Pelco Protocol Mode

 

The Pelco Mode features Auto Baud Detection that automatically detects and adjusts the

 

AutoDome protocol and baud rate to match that of the controller. The AutoDome responds to

 

Pelco-D or Pelco-P protocol commands.

 

 

 

NOTICE!

 

The AutoDome supports only the RS-485 protocol while in Pelco mode. It does not transmit

 

responses back to the controller.

 

 

4.2.1

Hardware Configuration

 

The AutoDome is configured from the factory for RS-485 operation in Pelco Protocol Mode.

 

1.

Connect the controller's TX terminals to the AutoDome's TxD terminals. See the

 

 

AutoDome Modular Camera System Installation Manual for complete wiring instructions.

 

2.

Pan or tilt the keyboard joystick to confirm that control has been established to the

 

 

AutoDome (approximately five (5) seconds).

NOTICE!

If control is not established, ensure that the RS-232/RS-485 selector switch is positioned to RS-485 (outward toward the LED lights). This switch is located on the bottom of the AutoDome CPU board, under the camera head and next to the LED lights. See Figure 4.1.

Figure 4.1 RS-232/RS-485 Selection Switch

1

2

3

4

CPU Module

Switch Location

LEDs

RS485

Bosch Security Systems, Inc.

User Manual

F.01U.270.005 2.0 2012.06

Page 33
Image 33
Bosch Appliances VG5 600 user manual Pelco Protocol Mode, Hardware Configuration