AutoDome 600 Series Analog PTZ CameraAlternative Control Protocols en 35

4.2.4

Special Preset Commands

 

 

Some Pelco mode preset commands have a special meaning and override the normal Pelco

 

 

preset function as follows:

 

 

 

 

 

 

Preset Command

Description

 

 

 

 

 

 

33-PRESET

Pans the AutoDome 180° (Flip).

 

 

 

 

 

 

34-PRESET

Goes to Zero Pan (original home position).

 

 

 

 

 

 

80-PRESET

Toggles the Synchronization Mode between Line Lock and Internal

 

 

 

(Pelco Frame Scan). This command is available if commands are

 

 

 

unlocked using the Main menu.

 

 

 

 

 

 

81-PRESET

Initiates Preset Tour 1.

 

 

 

 

 

 

82-PRESET

Initiates Preset Tour 2.

 

 

 

 

 

 

92-PRESET

Sets the Left pan limit for an AutoScan with Limit Stops enabled.

 

 

 

 

 

 

93-PRESET

Sets the Right pan limit for an AutoScan with Limit Stops enabled.

 

 

 

 

 

 

94-PRESET

Initiates a Preset Tour.

 

 

 

 

 

 

95-PRESET

Enables or disables Limit Stops in the Setup Menu for AutoScan.

 

 

 

Invokes the Pelco main Setup Menu when pressed for 2 seconds.

 

 

 

 

 

 

96-PRESET

Stops a scan.

 

 

 

 

 

 

97-PRESET

Initiates FastAddress (Pelco Random Scan).

 

 

 

 

 

 

98-PRESET

Toggles the Synch. Mode between Line Lock and Internal (Pelco Frame

 

 

 

Scan). This command is available only for two (2) minutes after the

 

 

 

power is applied and then reverts to normal preset functionality.

 

 

 

 

 

 

99-PRESET

Starts an AutoScan

 

 

 

 

NOTICE!

Some Pelco controllers do not support all the preset command numbers. Consult the specific Pelco controller's documentation for supported preset commands.

Bosch Security Systems, Inc.

User Manual

F.01U.270.005 2.0 2012.06

Page 35