M-Series User ’s Guide Appendix F - Permasleeve Printing

Printer Calibration

Once the media and ribbon are loaded and the media sensor is in place, the printer must be calibrated.

For the M-Series printer, this is accomplished by pressing the MODE Key until the CALIBRATE light is on and then pressing the FEED Key.

Note: Every time a different type or size of media is run (labels or Permasleeve), this Calibration procedure must be repeated.

Verifying Calibration

After the calibration process is completed, make sure the process was successful by pressing the FEED Key repeatedly, verifying that one sleeve is ejected per press of the FEED Key.

Once the calibration process is completed, the media can be rewound by opening the printhead, manually rewinding the material, and closing the printhead. The printer is now in the PAUSE Mode. Press PAUSE to take the printer out of PAUSE Mode. Five inches of material will then feed out. See leader instructions to eliminate this five inches of waste.

Leader Instructions

Whenever the Printhead is opened, the printer goes off-line and the PAUSE light is lit. To put the printer back on-line, press the PAUSE Key. When it is pressed, five inches of media is ejected.

This five inches of waste is avoided on the first print job of every new roll because there is a leader of empty carrier provided. When starting a print job in the middle of the roll, this empty carrier from the front of the roll can be cut off and reattached to the leading edge of the media. This should be reattached using cellophane (transparent) tape. This provides the user with a method of printing without wasting any sleeves.

F-3