Briggs & Stratton CE8069 Identification, Type of, Lead Wire Colors, Starter, Rewind, Gray/Gray

Models: 273521 276535 CE8069 270962 271172

1 179
Download 179 pages 13.96 Kb
Page 127
Image 127
Identification

8

Figure 26

Figure 27

There are two types of Oil Gard systems in use:

Start Sense

Run Sense

Identification

Start Sense is designed to prevent the engine from starting if the oil level is too low. It will not start an engine that is already running.

Type of

Lead Wire Colors

Starter

 

 

 

Rewind

Gray/Gray

 

Yellow/Black

 

 

Electric

Yellow/Yellow

 

 

Run Sense will stop a running engine if the oil level runs below the ADD level on the dipstick.

The engine can be restarted, but will only run briefly.

Type of

Lead Wire Colors

Starter

 

 

 

Rewind

Gray/Black

 

White/Gray

 

 

Electric

Gray/Black

 

White/Gray

 

 

Troubleshooting

In engines equipped with a Start Sense system, if the engine will not start, check oil level and bring level to FULL. If engine still does not start, disconnect lead at the oil fill plug/terminal. If engine starts, the module is faulty, or the internal crankcase float is sticking. Clean or replace parts as necessary.

In engines equipped with a Run Sense system, if the engine halts during operation, or will not remain running upon starting, check oil level. if oil level is at FULL and engine continues to halt, the module is faulty or the internal crankcase float is sticking. Clean or replace parts as necessary.