4. INSTALLATION | |
|
|
4) Installation underneath the work table
3878Q
Work table hole positions
2075Q | 3877Q | 3879Q |
Standard BROTHER work tables are provided with installation holes for use in installing the transformer.
1.Remove the four screws (1), and then remove the two handles (2).
2.Use the bolts (4), flat washers (5), spring washers (6) and nuts (7) to install the transformer as shown in the illustration, while leaving a gap of 2 mm between the work table and the cushion collars (3).
* Use the bolts, flat washers, spring washers, nuts and cushion collars which are included.
Connecting the cords
3880Q | 3881Q |
|
|
1.Loosen the four screws (1), and then remove the transformer cover (2).
2.Connect the control box connector (3) to the transformer connector (4).
3.Secure the connected cords with the cord holder (5) and the screw (6), and place them inside the transformer cover
(2).
4.Install the transformer cover (2) with the four screws (1).
5.Secure the cords to the work table using staples.
18 |