12. PROGRAM INITIALIZATION | |
|
|
. PROGRAM INITIALIZATION
3992Q
1.While pressing the RESET key (1), turn on the power switch.
* While initializing all programs, all LEDs on the operation panel will illuminate and the buzzer will sound continuously for 8 seconds.
2.Once all programs have been initialized, “-
Parameters
Memory switches
Production counter and lower thread counter
* If any cycle programs have been set, they will also be cleared.
3.Set the feed mechanism to the home position. (Refer to
1.Select the number of the program to be initialized, and then turn off the power.
2.While pressing the CUTTER ON key (4), turn on the power switch.
* The number of the program that will be initialized will appear in the program number LED (2), and then all other LEDs will illuminate and the buzzer will sound four times.
3.When all parameters of the selected program have been initialized, “-
Settings which are initialized
Parameters
4.Set the feed mechanism to the home position. (Refer to
80 |