5. OPERATION￿

￿

￿-￿-￿. Operating the standing operation pedal (option)

Note: Set the circuit board DIP switch 2 - No.1 to ON. (Refer to “13. CHANGING FUNCTIONS USING THE DIP SWITCHES”.)

Start pedal

Work clamp

pedal

Work clamp lifter pedal

Three pedals￿

When the work clamp pedal (middle) is depressed, the work clamp lowers, and when it is depressed once more, the work clamp returns to the neutral position.

When the start pedal (right side) is depressed, sewing starts.

When the work clamp lifter pedal (left side) is depressed, the work clamp rises while the pedal is being depressed. (functions in the same way as depressing the treadle backward.)

3908Q

When circuit board DIP switch 2 - No. 3 is set to ON, you can set the work clamp to lower while the work clamp pedal is being depressed.

31

HE-800A