5. OPERATION￿

￿

Symptom

 

 

Cause

 

Remedy

Parameter

number

35

If the sewing area is 4.0 mm and parameter

 

4.0 mm

A

(Eyelet

buttonhole

number 06 (Knife X space) is set to 0.4 mm

 

 

radius)

does

 

not

and parameter number 05 (Zigzag width) is set

 

 

 

become

larger

 

or

to 1.5 mm, the eyelet buttonhole radius that

 

 

 

smaller.

 

 

 

can be entered will be a minimum of (1.5 + 1.5

 

 

 

 

 

 

 

+ 0.4) ￿ 2 = 1.7 mm, and a maximum of 4.0 ￿ 2

 

 

 

 

 

 

 

= 2.0 mm.

 

 

 

 

 

 

 

 

1.5 mm

1.5 mm

 

 

 

 

 

 

 

0.4 mm

 

 

 

 

 

 

 

3925Q

 

Parameter

number

02

If the sewing area is 32.0 mm and parameter

 

 

A

(Length of

knife)

does

number 07 (Knife Y space) is set to 1.0 mm,

 

 

 

not become larger.

 

 

parameter number 21 (Front tack length) is set

 

 

 

 

 

 

 

to 1.0 mm and parameter number 31 (Rear

 

1.0 mm

 

 

 

 

 

tack length) is set to 1.0 mm, the knife length

 

 

 

 

 

 

will be 32.0 - 1.0 - 1.0 - 1.0 - 1.0 = 28.0 mm.

32.0 mm

1.0 mm

 

 

 

 

 

(The default setting is 27.8 mm to match the

 

 

 

 

 

 

 

positions of the needle and cutter.)

 

 

 

Parameter

number

07

See illustration.

 

 

 

(Knife Y space)

does

 

 

 

 

not become larger.

 

 

 

 

 

 

Parameter

number

21

See illustration.

 

1.0 mm

 

 

 

(Front tack length) and

 

 

 

 

parameter

number

31

 

 

1.0 mm

 

(Rear tack

length)

do

 

 

 

 

 

 

 

not become larger.

 

 

 

 

3926Q

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

number

13

The initial setting for parameter number 13

 

 

B

(Straight

bar

tack

(Straight bar tack length) is 13.0 mm, and for

 

 

 

length)

does

 

not

parameter number 17 (Running length) it is

 

 

 

become smaller.

 

 

11.0 mm. At this time, the straight bar tack

 

 

 

 

 

 

 

length cannot be set to less than 11.0 mm.

 

 

 

 

 

 

 

 

11.0 mm

13.0 mm

 

 

 

 

 

 

 

3927Q

 

 

 

 

 

 

 

 

 

<Remedy>￿

A. Change the work clamp over to a larger work clamp. Alternatively, change the needle plate to one with a larger hole. Note: Be sure to change the setting for panel DIP switch B also.

B. Set parameter number 17 (Running length) to a smaller value and then set the straight bar tack length.

47

HE-800A