5. OPERATION
Symptom |
|
| Cause |
| Remedy | ||
Parameter | number | 35 | If the sewing area is 4.0 mm and parameter |
| 4.0 mm | A | |
(Eyelet | buttonhole | number 06 (Knife X space) is set to 0.4 mm |
|
| |||
radius) | does |
| not | and parameter number 05 (Zigzag width) is set |
|
|
|
become | larger |
| or | to 1.5 mm, the eyelet buttonhole radius that |
|
|
|
smaller. |
|
|
| can be entered will be a minimum of (1.5 + 1.5 |
|
|
|
|
|
|
| + 0.4) 2 = 1.7 mm, and a maximum of 4.0 2 |
|
|
|
|
|
|
| = 2.0 mm. |
|
|
|
|
|
|
|
| 1.5 mm | 1.5 mm |
|
|
|
|
|
|
| 0.4 mm |
|
|
|
|
|
|
| 3925Q |
|
Parameter | number | 02 | If the sewing area is 32.0 mm and parameter |
|
| A | |
(Length of | knife) | does | number 07 (Knife Y space) is set to 1.0 mm, |
|
|
| |
not become larger. |
|
| parameter number 21 (Front tack length) is set |
|
|
| |
|
|
|
| to 1.0 mm and parameter number 31 (Rear |
| 1.0 mm |
|
|
|
|
| tack length) is set to 1.0 mm, the knife length |
|
| |
|
|
|
| will be 32.0 - 1.0 - 1.0 - 1.0 - 1.0 = 28.0 mm. | 32.0 mm | 1.0 mm |
|
|
|
|
| (The default setting is 27.8 mm to match the |
|
|
|
|
|
|
| positions of the needle and cutter.) |
|
|
|
Parameter | number | 07 | See illustration. |
|
|
| |
(Knife Y space) | does |
|
|
|
| ||
not become larger. |
|
|
|
|
|
| |
Parameter | number | 21 | See illustration. |
| 1.0 mm |
| |
|
| ||||||
(Front tack length) and |
|
|
|
| |||
parameter | number | 31 |
|
| 1.0 mm |
| |
(Rear tack | length) | do |
|
|
| ||
|
|
|
| ||||
not become larger. |
|
|
|
| 3926Q |
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
Parameter | number | 13 | The initial setting for parameter number 13 |
|
| B | |
(Straight | bar | tack | (Straight bar tack length) is 13.0 mm, and for |
|
|
| |
length) | does |
| not | parameter number 17 (Running length) it is |
|
|
|
become smaller. |
|
| 11.0 mm. At this time, the straight bar tack |
|
|
| |
|
|
|
| length cannot be set to less than 11.0 mm. |
|
|
|
|
|
|
|
| 11.0 mm | 13.0 mm |
|
|
|
|
|
|
| 3927Q |
|
|
|
|
|
|
|
|
|
<Remedy>
A. Change the work clamp over to a larger work clamp. Alternatively, change the needle plate to one with a larger hole. Note: Be sure to change the setting for panel DIP switch B also.
B. Set parameter number 17 (Running length) to a smaller value and then set the straight bar tack length.